Calculator
Inverter Sizing and DC/AC Ratio Calculator
Inverter sizing is two questions wearing one name. The first is electrical: will the string voltage stay inside the inverter's window on the coldest morning and the hottest afternoon of the year? The second is economic: how much DC capacity should sit behind each kilowatt of AC output before clipping costs more than the extra panels earn?
Get the first wrong and the inverter trips, fails or voids its warranty. Get the second wrong and you either throw away summer peaks or pay for inverter capacity that is used for twenty hours a year.
Check your configuration
Negative, e.g. −0.25
Array DC capacity
7.04 kWp
DC/AC ratio
1.17
1.10 to 1.30 is the usual window
Strings
2.00
Whole strings
Voc at -10°C
335 V
Within limits
Vmp at 70°C
230 V
Must stay above the inverter MPPT minimum
String design current
17.8 A
Isc × 1.25 for protection sizing
Estimated clipping loss
0.3%
Annual energy, order-of-magnitude only
How the calculation works
Figure — Three conversion architectures
Decision tree
String, optimiser or microinverter
Architecture is decided by the roof, not by preference. Answer in order and stop at the first branch that terminates.
Does any part of the array suffer unavoidable partial shade during generating hours?
- Yes, on some modules
- → go to step 2
- No
- → go to step 3
Is the shade confined to a minority of modules?
Shade on a handful of modules is a module-level problem. Shade across the whole array is a siting problem no electronics can fix.
- A few modules
- Optimisers on the affected modules, or microinverters if the roof is complex as well as shaded.
- Most of the array
- Reconsider the location. Distributed electronics recover a fraction of the loss at full hardware cost.
Does the array span more than two roof planes or orientations?
- Yes
- Microinverters, or a multi-MPPT string inverter with one plane per tracker.
- No
- → go to step 4
Do local rules require module-level rapid shutdown?
Common in North America under NEC 690.12; increasingly requested by insurers elsewhere.
- Yes
- Optimisers or microinverters, which satisfy the requirement inherently.
- No
- A string inverter. Fewest components on the roof, highest conversion efficiency, lowest cost per watt.
Open-circuit voltage rises as cells get colder, and the coldest sunny morning of the year is the design case. Multiply the module Voc by the number in series, then apply the temperature coefficient across the difference between the record low cell temperature and the 25°C standard test condition. The result must sit under the inverter's absolute maximum DC voltage with margin.
The opposite case is a hot roof: maximum power point voltage falls, and if the string drops below the inverter's MPPT window the tracker loses the array. Current sizing follows the same logic with a 1.25 factor applied to short-circuit current for continuous-duty protection.
The formula
Voc(cold) = n × Voc_STC × (1 + β/100 × (T_min − 25)) → must be < V_dc,max Vmp(hot) = n × Vmp_STC × (1 + β/100 × (T_max − 25)) → must be > V_mppt,min I_design = Isc × 1.25 DC/AC = P_dc,array / P_ac,inverter n modules per string · β Voc temperature coefficient (%/°C) T_min record low cell temperature · T_max hot-roof cell temperature
Assumptions behind the numbers
- Cell temperature, not air temperature. On a cold clear morning cell temperature approaches ambient; on a hot roof it runs 25 to 30°C above ambient.
- The Vmp temperature coefficient is approximated with the Voc coefficient here. Datasheet Vmp coefficients are usually slightly more negative, so treat the hot-string figure as mildly optimistic.
- Clipping is a rough bell-curve approximation. Real clipping depends on orientation, climate and inverter behaviour; model it in PVsyst or PVGIS for anything commercial.
- All modules in a string are identical, coplanar and unshaded. Mixed orientations need separate MPPT inputs.
- The 1.25 factor reflects common practice for continuous current; national wiring rules may require more.
- Grid codes may cap exported AC power independently of inverter rating.
How to read the result
A DC/AC ratio between 1.10 and 1.30 is normal and desirable. Below 1.0 you are paying for inverter capacity that never fills. Above 1.35 clipping starts to bite in sunny climates, though east-west arrays and northern latitudes tolerate higher ratios because their production curve is flatter.
Voltage results are pass or fail, not preferences. If cold Voc exceeds the inverter maximum, shorten the string by one module. If hot Vmp falls under the MPPT minimum, lengthen it. Both constraints must hold simultaneously, which is what fixes the module count per string.
Worked example
Sixteen 440 Wp modules, Voc 38.5 V, Vmp 32.4 V, coefficient −0.25%/°C, in two strings of eight behind a 6 kW hybrid inverter rated to 1,000 V DC.
Array DC is 7.04 kWp, so the DC/AC ratio is 1.17 — comfortably inside the usual window. At a record −10°C, string Voc is 8 × 38.5 × (1 + (−0.0025 × −35)) = 335 V, far below the 1,000 V ceiling; the string could safely be longer. At a 70°C cell temperature, string Vmp falls to 8 × 32.4 × (1 − 0.1125) = 230 V, above a typical 125 V MPPT minimum. Both constraints pass, and with a ratio under 1.2 clipping is negligible.
Mistakes that skew the answer
- Using ambient rather than cell temperature for the cold-voltage check, which understates string voltage by tens of volts.
- Ignoring the record low for the site and using an average winter temperature instead.
- Splitting an east-west roof across one MPPT input, so the tracker compromises between two different curves.
- Sizing the inverter to nameplate DC and paying for capacity that is used a handful of hours a year.
- Overlooking the export limit imposed by the network operator, which can make a larger inverter pointless.
- Mixing module types or ages within a string, which drags the whole string to the weakest current.
Questions readers ask
- What DC/AC ratio should I use?
- For a south-facing array in southern Europe, 1.10 to 1.20 keeps clipping under about 1% of annual energy. In northern climates or on east-west roofs, 1.25 to 1.40 is often the better economic choice because the production curve rarely reaches the inverter ceiling. Commercial projects with export limits sometimes run 1.5 or higher deliberately.
- Is clipping bad?
- Mild clipping is a deliberate trade. Modules are cheaper per watt than inverters, so accepting the loss of a few peak hours in exchange for much better morning and evening output usually raises annual yield per euro. Clipping becomes a problem when it exceeds roughly 2 to 3% of annual energy or when it coincides with your highest-value export hours.
- Can I install an inverter larger than my array?
- Yes, and it is sometimes sensible if you plan to expand the array or add DC-coupled storage later. The cost is efficiency: inverters are least efficient at very low load fractions, so a heavily oversized inverter loses a little energy every day. Check the efficiency curve at 10 to 20% load before deciding.
- How do microinverters change this?
- Microinverters move the sizing decision to module level, so the DC/AC ratio is fixed per unit and string voltage limits disappear. The trade is cost per watt and having power electronics on the roof. For complex or shaded roofs, that per-module independence often outweighs the price difference.
- What margin should I leave on maximum DC voltage?
- Aim for at least 5% headroom below the inverter's absolute maximum after the cold-temperature calculation, and use the coldest recorded temperature for the site rather than a typical winter minimum. Exceeding maximum DC voltage even briefly can destroy input stages and is explicitly excluded from most warranties.
References
Related tools and reading
Cable sizing and voltage drop
Size the DC and AC runs once the strings are fixed.
Payback and ROI calculator
See what clipping and array size do to the economics.
Solar inverters explained
Topologies, ratings and protections in plain terms.
Hybrid, string and microinverters
Choosing the right architecture for a roof.